National Air Filters is a leading HEPA filter manufacturers in Talegaon. We are trusted suppliers and dealers in Talegaon, Pune. We manufactured and supplied HEPA and industrial air filters from Pune since 2017. We make standard and custom-size HEPA filters for manufacturing plants, pharmaceutical and food units, laboratories, cleanrooms, hospitals and commercial buildings across Pune, including Talegaon MIDC, Talegaon Dabhade and the nearby Chakan, Induri, Vadgaon Maval and Dehu Road belts. Our work to date covers 800+ projects for 760+ customers.
If you are looking for HEPA filter manufacturers, suppliers or dealers in Talegaon, send us your filter size, grade and airflow, or the model number of your existing filter. We will help you match it to your air handling unit (AHU), terminal box or filtration unit.
A HEPA (High-Efficiency Particulate Air) filter traps fine airborne particles such as dust, pollen, mould spores and particles that carry microorganisms. Under the US standard, a True HEPA filter captures at least 99.97% of 0.3-micron particles. Under the European standard EN 1822 / ISO 29463, filters are graded at their most penetrating particle size (MPPS).
The filter media works through three mechanisms:
A HEPA filter performs well only when it is correctly selected, sealed and maintained. A pre-filter upstream protects the HEPA filter and extends its service life.
| Type | Efficiency / Design | Typical Use |
|---|---|---|
| H13 HEPA filter | Minimum 99.95% at MPPS | Hospitals, laboratories, pharmaceutical AHUs, commercial HVAC |
| H14 HEPA filter | Minimum 99.995% at MPPS | Operation theatres, pharmaceutical production, critical cleanrooms |
| Mini-pleat HEPA filter | Closely spaced pleats, large media area in a compact frame | Cleanroom terminal units, FFUs, AHUs |
| Deep-pleat HEPA filter | Deeper pleats with separators and rigid frame | Industrial ventilation, central AHUs, higher airflow |
| Box-type HEPA filter | Media enclosed in a rigid frame or housing | Ceiling systems, AHUs, industrial filtration |
| Gel-seal HEPA filter | Gel channel seal to limit bypass at the mounting frame | Pharmaceutical and controlled-environment cleanrooms |
| V-bank HEPA filter | Multiple packs in a V arrangement | Commercial and industrial AHUs needing higher airflow |
All filters are available in GI or aluminium frames, in standard and custom sizes. For ceiling-mounted installations, we also supply HEPA terminal boxes. For dusty plant air, we also supply pre-filters and pocket filters to sit upstream of the HEPA stage.
| Parameter | H13 | H14 | Mini-Pleat | Deep-Pleat | Gel-Seal | V-Bank |
|---|---|---|---|---|---|---|
| Efficiency at MPPS | Min. 99.95% | Min. 99.995% | H13 or H14 | H13 or H14 | H13 or H14 | As specified |
| Typical sizes (mm) | 305×305×150; 610×610×150 | 305×305×150; 610×610×150 | 305×305×70; 610×610×70 | 610×610×292 | 610×610×90; 610×610×150 | 592×592×292; 610×610×292 |
| Indicative airflow (m³/h) | 150–1,000 | 150–900 | 150–1,200 | 500–2,000 | 500–1,200 | 1,000–3,500 |
| Initial pressure drop (Pa) | 100–250 | 120–300 | 80–250 | 150–300 | 100–250 | 100–300 |
| Test standard | EN 1822 / ISO 29463 | EN 1822 / ISO 29463 | As certified | As certified | As certified | As certified |
Talegaon MIDC and Talegaon Dabhade combine automotive, engineering, plastics, food, FMCG and pharmaceutical units with a growing town of hospitals, clinics, schools and colleges. HEPA filtration is typically specified for:
The right grade depends on your applicable standard, such as ISO 14644 cleanroom class, GMP requirements for pharma, or hospital ventilation guidelines. Your designer or validation team should confirm the grade.
Units in Talegaon MIDC that work under GMP, food-safety or customer audits are often asked to show records for their HEPA filters. Keep these on file for each filter:
National Air Filters
1st Floor, Survey No. 132/3/1, Saswad Road, Urali Dewachi, Haveli, Pune, Maharashtra 412308
Phone: +91 7887549853 | +91 8975495013
Email: info@nationalairfilterspune.com
Ans: They remove fine airborne particles in hospitals, laboratories, cleanrooms, pharmaceutical units, food and packaging plants, industrial plants and commercial HVAC systems.
Ans: Ask for the filter's grade and specification, the test report or certificate for that grade, and the dimensions and rated airflow. After installation, keep your own integrity test, particle count and pressure drop records.
Ans: We supply H13 and H14 filters in mini-pleat, deep-pleat, box-type, gel-seal and V-bank designs, plus HEPA terminal boxes, pre-filters and pocket filters, delivered from our Pune facility.
Ans: Yes. We can make filters to your size, frame material (GI or aluminium) and grade. Share your drawing or existing filter details for a quote.
Ans: No. Washing or cleaning can damage the media and the seal. Clean or replace the pre-filters more often to protect the HEPA filter.
Ans: There is no fixed lifespan. It depends on dust load, airflow, operating hours and pre-filtration. Facilities usually replace a filter when its pressure drop reaches the limit set by the manufacturer, or if an integrity test fails.
Ans: Replace it if the pressure drop reaches the manufacturer's final limit, airflow falls, the filter is visibly damaged, or a leak test fails.
Ans: Price depends on grade, size, construction, frame material and quantity. Send us your requirements for a quotation.